Scope, and What Goes on Paper
When a Level 2 finds cracked tiles, missing mortar joints or a flue the wrong size for a new insert, relining is usually the answer. We size the liner from the appliance data, drop the stainless run from the roof, join it at the base, add an insulating blanket if the brick sits close to framing, and close the top. Video of the old flue and the new run goes into one report.
What a liner fixes, and how the report shows it
Inside most older brick chimneys is a stack of clay flue tiles. They carry smoke and heat up and away from the brick and the wood framing it touches. When a tile cracks or a joint between tiles opens, that protection has a hole in it, and the next hot fire can push heat or sparks somewhere they should not go. A Level 2 camera pass is how those holes are found, and the report shows them as still frames with the height of each: a split tile at nine feet, an open joint at fifteen. A second reason for a liner shows up in the same report: the flue is the wrong size for what it now serves. A gas insert or a stove venting into a large old fireplace flue gets a weak draft and wet, acidic exhaust that eats at the mortar. The report sets the flue's inside size against what the appliance calls for.
A liner is a continuous stainless steel pipe threaded down through the old flue from above, joined to the appliance or the smoke chamber at its lower end, and capped where it leaves the crown. It turns the inside of the chimney into one smooth, sealed passage of the right size, without opening any brick. For wood fireplaces and stoves, the pipe is often wrapped in insulation, which keeps the flue hot so smoke rises well and less creosote forms, and which supplies the gap to framing that an old chimney may lack. For gas, a lighter pipe without wrap is usually enough. Where the old flue is too narrow for a round pipe of the needed size, oval and rectangular liners exist, and the quote names the shape and type your chimney gets along with the reason for the choice.
What the liner quote covers
The quote starts with the pipe: its diameter, its grade of steel and its length from the appliance to the top. Then the wrap, if your appliance and the clearances call for one. At the base comes the fitting that joins the pipe to whatever burns below it, which differs for a stove, an insert and an open fireplace. At the crown comes a sealing plate across the old flue and a cap over the pipe. Last come any clearing jobs needed to make room, such as taking out the old damper frame or knocking off a ledge of mortar that would snag the pipe on its way down. Each has its own figure. Taller chimneys and wood-burning appliances need more material; short runs for gas need less. Damage the camera found elsewhere, like a cracked crown, sits on a separate line so you can see it apart from the liner.
Lining is usually the final step in a sequence that begins with the Level 2 at $410. The camera frames show the problem, the liner fixes it, and the completion note records the liner's make, diameter and length so the next inspector knows exactly what is in the chimney. That paperwork matters in a sale, since a buyer's inspector reading relined with no details will ask questions that a model and a length answer at once. Insert projects often fold the liner into the insert quote, within our $2,950 to $5,900 range. For a fireplace or stove on its own, the liner is quoted by itself. To start, book the Level 2 through the contact form, or, if another inspector has already filmed the flue, mention those findings when you write so we can read them before we come out.
How Winfield Chimney Group Documents This Work
Photo First
Each finding pictured before anything is priced
Plain Grades
Sound, monitor or repair before use, with a reason
Keyed Quotes
Each price line points to a numbered finding
Closing Photos
The same spots shown again once the work is done
Cities With a Chimney Liner Installation Page
Pick a city to read what our reports there tend to find, the houses involved and the ZIP codes covered.
That name is not on our list for this service. Check the spelling, or see every city on the areas page.
More Services
Chimney Sweep
Creosote and soot lifted from the flue, smoke chamber and firebox, with a short written note on what the brushes brought down.
Scope and report →Chimney Inspection
A graded chimney report: every part from firebox to cap rated, photographed and paired with a plain next step.
Scope and report →Chimney Repair
Repairs scoped from our own report, each fix tied to a numbered finding, its photo and a written figure you approve first.
Scope and report →Fireplace Inspection
The room side of the system rated in writing: firebox walls, damper, smoke chamber, hearth extension and mantel distance.
Scope and report →Fireplace Repair
Firebox, damper and smoke chamber faults from the report put right, then photographed again for the file.
Scope and report →Chimney Level 2 Inspection
Video of the liner from the smoke chamber up, attic and roof sections checked, and still frames in the report.
Scope and report →Chimney Cap Installation
A new top for the flue, sized from measurements we take on the roof and recorded in a photo once fitted.
Scope and report →Chimney Flashing Repair
Roof-line metal around the stack resealed or renewed after we find exactly where water slips past it.
Scope and report →Chimney Masonry Repair
Brick and mortar faults from the report fixed: eroded joints, spalled faces and cracked courses, matched to the existing wall.
Scope and report →Chimney Rebuilds
A stack the report rates beyond patching taken down and laid again, from the roofline or lower if the damage runs deep.
Scope and report →Fireplace Cleaning
Ash, soot film and glass haze removed from the firebox and doors, with a quick written note on what we saw.
Scope and report →Gas Fireplace Cleaning
A gas unit's ports, pilot, log set and glass serviced, then a carbon monoxide reading taken and written on the report.
Scope and report →Gas Fireplace Repair
Gas units that refuse to light, drop the pilot or run with a poor flame diagnosed, with the readings written down.
Scope and report →Fireplace Remodel
A fresh face, mantel or hearth for the fireplace, started only after an inspection confirms the firebox and flue behind it.
Scope and report →Fireplace Inserts
Gas, wood or electric inserts fitted after a flue report confirms the opening and liner path; gas units installed $2,950 to $5,900.
Scope and report →Pellet Stove Repair
Pellet stoves that stop mid-burn or throw codes tested part by part, with the failing component named in writing.
Scope and report →Wood Stove Repair
Door gaskets, baffles, firebrick and glass on wood stoves renewed after a check that lists every worn part.
Scope and report →Gas Logs
Log sets matched to the opening and flue after a check of both, installed with a leak test and a CO reading.
Scope and report →Chimney Seismic Retrofit
Brick stacks assessed for quake risk, with bracing, strapping or a lighter upper section priced as options in the report.
Scope and report →Chimney Crown Repair
Cracked or flat crowns sealed or recast after a roof check that photographs every crack and the flue tile around it.
Scope and report →Dryer Vent Cleaning
Lint packed in the duct between the machine and the outside hood cleared, with airflow noted before and after.
Scope and report →Chimney Leak Repair
Water inside near the chimney traced to its entry point, documented with photos, then fixed for $590 to $3,500.
Scope and report →Chimney Waterproofing
A breathable repellent on brick that has passed inspection, so wind-driven rain stays out while damp inside can still dry.
Scope and report →Chimney Damper Repair
Dampers that bind, leave a gap or have rusted out repaired or replaced, including top-mounted models worked by a cable.
Scope and report →Chimney Chase Cover
Rusted or sagging metal lids on framed chimneys replaced with a custom stainless cover that sheds water off the edges.
Scope and report →